Mounting |
Renishaw autojoint : PH10M, PH10MQ or PH6M
May be mounted on autojoint extension bars |
Suitable interface |
Either: UCC controller
Or: AC3 PC interface card for machines not fitted with the UCC controller |
Probe attributes |
3-axis analogue measurement (X, Y, Z)
Pivoting motion in XY plane with translation in Z direction
For SM25-5: Plane translation in all 3 axes XYZ |
Measurement range |
±0.5 mm (±0.02 in) in X, Y and Z
For SM25-5: ±0.3 mm |
Overtravel range |
±2.0 mm (±0.08 in) in X and Y
1.7 mm (0.07 in) in +Z
1.2 mm (0.07 in) in –Z
For SM25-5:
±X, ±Y = 0.95 mm (0.037 in)
+Z = 1.0 mm (0.039 in)
-Z = 1.1 mm (0.043 in) |
Crash protection |
X, Y, –Z - break-off of either module or stylus holder
+Z - integral bump-stop design |
Resolution |
< 0.1 µm (0.000004 in) with either UCC2 daughtercard or AC3 interface card |
Spring rate |
0.2 N/mm to 0.6 N/mm nominal dependent on stylus length |
Damping |
Single viscous fluid damper
For SM25-5: Two viscous fluid dampers |
Power supply |
+12 V (±5%), –12 V (+10% / –8%), +5 V (+10% / –13%) DC at probe |
Outputs (X,Y,Z) |
Non-linear and non-orthogonal analogue outputs - rate, gain and resolution are not fixed
SP25M requires that a non-linear, third-order polynomial calibration method is used. |