Item
Data
APPROVAL
Test standard IEC/EN60998-1£º2004 / UL1059
Pitch [mm] 3.5/3.96
Poles 02-24P
EN60998 Test data 40022177
Rated voltage [V] 130
Rated current [A] 10
Rated connection capacity(solid/stranded) [mm²] 0.5-1.0
Surge voltage category/pollution degree/material group III/2/I
Withstanding Voltage [KV/min] 1.25
Rated torque [N.m] 0.2
UL1059Test data UL File Number E228872
Use group B C D
Rated voltage [V] 300 / /
Rated current [A] 7 / /
Rated connection capacity (solid/stranded) [AWG] 24~18
Rated torque [Lb. in] 1.77
General data /
Screw M2
Inflammability classUL94 V-0
Ambient temperature [¡æ] -40~+105
Relative humidity 5%-95%
Inspection standard MIL-STD-105E II
AQL 0.65
Warranty 12 months
Material and plating /
Housing PA66
Screws Steel£¬Zn plated
Contact Copper alloy£¬Sn Plated
Wire protector Stainless steel
Wire connecting
Recommended stripping length5-6mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.