MEASURED VALUE
Temperature
Relative humidity
Counted values (dew point…)
Atmospheric pressure
TEMPERATURE SENSOR
Measuring range -30 to +60 °C
Accuracy ±0.4 °C
Resolution 0.1 °C
HUMIDITY SENSOR
Measuring range 0 to 95 % RH
Accuracy ±1.8 % RH from 0 to 90 % at 23 °C
Resolution 0.1% RH
DEW POINT
Measuring range -60 to +60 °C
Accuracy ±1.5 °C at ambient temperature T < 25 °C and RH > 30 %
Resolution 0.1 °C
ATMOSPHERIC PRESSURE SENSOR SENSOR
Measuring range 600 to 1100 hPa
Accuracy ±1.3 hPa at 23 °C
Resolution 0.1 hPa
GENERAL TECHNICAL DATA
Operating temperature -30 to +60 °C
Channels sensor of temperature, humidity sensor and atmospheric pressure
Measuring interval 1 s
Sending interval to COMET Cloud adjustable 5 minutes to 12 hours
Communication protocols HTTP(S), SMTP, ModbusTCP, HTTP POST, HTTP GET (JSON, XML)
Alarm signalization e-mail, acoustic, LED
Power 5.0 to 5.4 VDC; consumption 150 mA (max. 500 mA); USB-C connector
Radio section frequency: 2.4 GHz; max. transmit power: 18 dBm; standard: IEEE 802.11 b/g/n
Protection class IP30
Dimensions 156 x 93 x 32 mm
Weight 125 g
Warranty 3 years